Transcranial magnetic Stimulation

TMS Navigator

TMS Navigator Scalable Solutions

High end neuronavigation

Tailored to your demands

Whether in research or medical applications: The Localite TMS Navigator enables navigated brain stimulation at the highest level. Available in numerous variants and configurations, our system can be individually tailored to your needs. And the ergonomics are just right too. Quality you can feel in your daily work.

Compact setup with a mobile equipment cart or an MR-compatible system for navigation in the MR scanner: There is a solution for every requirement. We even offer support for a robot/cobot.

Benefits

Outstanding benefits

Precise

Precise

Gold standard infrared tracking technology proven in surgical applications.

Versatile

Versatile

Predefined targets from renowned publications or individual targets based on brain atlases, functional or anatomical data.

Intuitive

Intuitive

Effortless guided coil (re-)positioning to reach targets.

Individual

Individual

Navigation using individual MRI data or personalized MNI-based brain.

Structured

Structured

Step-by-step wizards for core functions; hands-free operation with foot switch control.

Integrated

Integrated

Automated workflow and online stimulation marker recording with a variety of integrated TMS coils.

Software options

Tailored to individual needs

Exact positioning based on individual MRI data – maximum precision thanks to landmarks and surface registration.
A standard MNI head is individually adapted to the patient. Established stimulation paradigms such as F3-Beam can also be precisely implemented without MRI.
The overlay of functional data (fMRI) extends the application possibilities. Supported data formats are DICOM, NIfTI and Analyze.
The magnetic field is calculated for a large number of supported coils. The visualization enables immediate quality control of the stimulation.
Performed stimulations can be recorded and linked to stimulation responses (e.g. MEP). This generates comprehensive documentation that can be exported as an fMRI dataset.
A strong partnership! MV stimulators can be controlled directly via the navigation system. Changes made to the stimulator are also instantaneously displayed in the user interface.
The robotic extensions create integration with Axilum Robotics products. The fully automatic coil positioning facilitates the application, supports navigation sequences, and compensates for patient movements.
MR Based TMS navigator software features
TMS software features functional data
E-field stimulation TMS navigator software features
TMS software features stimulation response report
TMS software features MV stimulator connection
Cobot extension TMS navigator software features
Exact positioning based on individual MRI data – maximum precision thanks to landmarks and surface registration.

A standard MNI head is individually adapted to the patient. Established stimulation paradigms such as F3-Beam can also be precisely implemented without MRI.

The overlay of functional data (fMRI) extends the application possibilities. Supported data formats are DICOM, NIfTI and Analyze.

The magnetic field is calculated for a large number of supported coils. The visualization enables immediate quality control of the stimulation.

Performed stimulations can be recorded and linked to stimulation responses (e.g. MEP). This generates comprehensive documentation that can be exported as an fMRI dataset.

A strong partnership! MV stimulators can be controlled directly via the navigation system. Changes made to the stimulator are also instantaneously displayed in the user interface.

The robotic extensions create integration with Axilum Robotics products. The fully automatic coil positioning facilitates the application, supports navigation sequences, and compensates for patient movements.

Regulatory affairs

In the EU, Localite TMS Navigator products and accessories are CE marked medical devices.

In the U.S., only Localite TMS Navigator TS is FDA cleared for following intended use:

The TMS Navigator TS helps users to plan, implement and document treatment involving TMS of the brain. The system provides planning and navigation functions using anatomical MR data. Regions of the brain to be stimulated can be determined on the basis of anatomy, functional areas or by entering previously calculated coordinates from brain atlases.

The product is intended for use with the MagVenture therapy systems supplied by Tonica Elektronik A/S (Farum, Denmark), more precisely the R20 and R30 stimulators, the R30 TMS stimulator with MagOption, the X100 stimulator and the X100 stimulator with MagOption only with following magnetic coils: C-100, C-B60, Cool-B65, Cool-B70, Cool D-B80, MC-125, MC-B70, MCF-75, MCF-125, MCF-B65 and MMC-140-II.

Testimonials

Voices about our work

Reliable neuronavigation of the TMS coil, preferably based on individual MRI scans, is a key requirement for state-of-the-art therapeutic approaches. The possibility to further account for functional brain imaging information and personalized electric field simulations brings targeting accuracy to the next level.

Prof. Dr. Til Ole Bergmann | Acting Director NeuroImaging Center (NIC), University of Mainz

Prof. Dr. Til Ole Bergmann

Localite has proven to be an excellent partner in the field of navigated transcranial magnetic stimulation. Their dedication to quality and accuracy is of highest importance for precise and individualized brain stimulation. Our research combines various state-of-the-art brain stimulation and mapping approaches. Localite has been very supportive over the years, accommodating their products to our unique needs.

Prof. Hartwig R. Siebner | Director, Danish Research Centre for Magnetic Resonance, Copenhagen

Prof. Hartwig Siebner

The best in class quality and FDA clearance of Localite’s navigation products instills trust in the SAINT neuronavigation technique.

Christian Gormsen | President and CEO of Magnus Medical, Burlingame

Christian Gormsen

Configuration Guide

Adapt to your demand

Please enable JavaScript in your browser to complete this form.

Clickfunnel researcher or user

Question 1 / 3 

Are you a Researcher or Clinical User?

Researcher or Clinical User

Talk to a TMS expert

Have questions or need guidance? Our experts are here to help. Click below to connect with us and get personalized support.

Hardware

Reliable instruments for precise navigation

EEG PinPoint Hardware

Pointer ST

Particularly light pointer for patient registration.

Patient reference Hardware

Pointer MR

MR-compatible pointer milled from titanium.

Patient Reference Adhesive Head Tracker

Patient Reference

Ergonomically shaped patient reference for sticking on.

Alternative Patient Reference

Alternative Patient Reference

Patient reference tracker with headband.

TMS Coil Tracker Hardware

TMS-Coil Tracker

Adjustable tracker for MagVenture coils with round handle.

Tracker Brackets

Tracker Brackets

Tracker Brackets in various sizes.

Universal Coil Tracker

Universal Coil Tracker

Universal clamp mountable on all TMS coils featuring a coil handle.

Calibration plate Hardware

Calibration plate

Precise characterization of TMS coil hotspot.

Other Pages

Our support for research and healthcare

For researchers

Familiar with your needs

For clinical users

Support tailored to your demands